DIPSWITCH SETUP
Single button and
radio in SEQ mode
Single button and
radio in COM mode
timer
from mid-stop only
from both mid-stop
selected to enable a timer
reverse
1.5 seconds
0.5 seconds
sec delay on reverse for all
NOTE: If motor direction is reversed, the open and close limit switches are automatically reversed. However, the advanced
close limit switch needs to be manually changed. To do this, disconnect the 2 wires from the advanced closed limit switch
and re-connect to the auxiliary limit switch provided.
STATUS LED
-Primary safety devices not connected to P1 & P2
or not functioning properly
- Safety devices are activated
- 10k Ohm resistor (between S1 & S2) removed or
faulty
- Interlock is activated.
- Interlock jumper is not connected.
- Run-out timer has elapsed
- Delay on close timer is counting.
- Selector dial is set to Run-timer.
Timer to close is counting.
-Primary safety devices not connected to P1 & P2
or not functioning properly
- Safety devices are activated
- 10k Ohm resistor (between S1 & S2) removed or
Door is at Mid-stop position.
Close limit switch is activated.
Open limit switch is activated.
OFF
-
Stop button connected and functioning
- Stop push button is activated (or stop circuit is
- Close relay is activated.
- Open relay is activated.
24 VAC power to logic board is ON.