Micanan PRO-TB Manuel du propriétaire Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
3) Check the Battery voltage first. (The Receiver can not tell the difference between a dead battery and a
bad edge) Minimum 7 Volts. Replace battery if voltage is at or below minimum.
2) Make sure that the limits are adjusted so the safety edge impacts the floor hard enough to activate the
safety edge on CLOSE. (The Transmitter must send a signal to the Receiver at the bottom of the opening
for the unit to function properly during the next cycle)
DIP SWITCH CONFIGURATIONS
RECEIVER SWITCH SETTINGS
12345
ON
OFF (0) OFF (0)
ON
54321
TRANSMITTER SWITCH SETTINGS
6 7 8
TROUBLESHOOTING
1) Verify address selection dip switches (1 thru 4) are set the same on the Transmitter and Receiver.
ADDRESS
SELECTOR
SELECTOR
ADDRESS
FACTORY SET
DO NOT ADJUST
6
Open door several feet - Verify that unit is still in "Supervised Mode". Constant3)
Reconnect sensing edge to Transmitter.4)
5) Close door completely:
Unit will switch to "Normal Mode" (within 3 sec).
- (D6) "Normal Mode" (GRN) LED will light. Door now requires momentary
contact for CLOSE control.
pressure required on door CLOSE control.
4) Verify that the extra, dedicated Auxiliary Close Limit Switch is adjusted so that it trips less than 6" off
the floor. If not adjusted correctly the unit will not remain in "B2", "Normal" mode.
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Commentaires sur ces manuels

Pas de commentaire